Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator

Product Details
Customization: Available
Warranty: 1 Year
Acting Form: Single-Acting
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2004

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (26)
  • Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
  • Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
  • Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
  • Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
  • Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
  • Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
Eaton Vickers V10 V20 Series
Type
Vane Pump
Displacement
Variable Pump
Performance
Corrosion
Pressure
High Pressure
Structure
Vane Pump
Max Pressure
17.2-19MPa
Usage
Oil
Power
Hydraulic
Application
Other
Fuel
Hydrauilc Oil
Theory
Rotary Pump
Transport Package
Standard
Specification
standard
Origin
China
Production Capacity
2000

Product Description

Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
1 YEAR WARRANTY AND EXCELLENT SERVICE
7 DAYS REFUND PAYMENT IN CASE OF QUALITY
24 HOURS SMOOTHLY COMMUNICATION
 
Offers original and replacement Eaton Vickers V10 V20 Series pressure switch for our customers. We will save customer costs, increase productivity and profit margins, Welcome to Get Latest Price now!
 
Product Description

Model Number:V10/V20
Place of Origin:Zhejiang, China
Pressure:High Pressure
Structure:vane pump
Max pressure(MPa):17.2MPa-19MPa
Usage:Oil
Power:Hydraulic
Application:Other
Fuel:hydrauilc oil
Theory:Rotary Pump
Standard or Nonstandard:Standard
Warranty:1 Year


1.In installation, the tolerance of concentricity between shaft of pump and motor must be less than 0.10mm(TIR) by using the flexible coupling; The pump shaft shall not bear the radial and axial load ; The carrier must be firm with good rigidity and can fully absorb vibrations.
2. Fix pipes, especially inlet pipes in accordance with the size of port and assemble safety relief valves in the system. The regulating pressure of the safety valve shall not be greater than the maximum pressure of the pump; Inlet pipes must be strictly sealed with no leakage; The fuel tank shall be equipped with a diaphragm to separate the bubbles and dirt from the oil; The oil return nozzle should be lower the fluid surface, the minimum depth of 50mm, even in a low, too, when the permissible level of to avoid the formation of bubbles .
3.Set the suction pressure at pump inlet port : Oil hydraulic oil is + 35 ~ -16.7KPa. The hydraulic oil of water - glycol and phosphate ester was + 35 ~ -10.1KPa.
4.In case where the pump is installed on the tank or at the position higher than the tank top cover, the height of the suction port of the pump should be less than 500mm.
5.Oil should be kept clean, pipes and tanks must be thoroughly cleaned; Precise filters should be assembled with the advised precision of 25μm in the system, the cleanness level of oil should be within NSA12. Fix the sufficient-volume filter (the rated flow rate should be greater than twice the pump flow )at the inlet of the pump 50mm above the bottom of the tank, with the suggested precision of 100μm(150 mesh).
6.Pumps can be used with anti-wear hydraulic oil, or automotive type crankcase oil (designations SC, SD, SE, SF, or SG) per SAE J183 JUN89. Fire-resistant fluids can also be used, but may require the use of special seals. The viscosity range of petroleum oil, with the pump running, should be 13-54 cSt. The oil viscosity at 38 ºC should be 32-48cSt. Fire-resistant fluids should have a viscosity as close as possible to that of petroleum oil as described above. A maximum specific gravity of 1.3 is suggested for fire resistant fluids. An operating temperature of 49 ºC is recommended. The maximum temperature for oil should be 65 ºC , and the maximum for water-containing fluids should be 54 ºC .
7.Seals nitrile: Seals are standard and are suitable for use with petroleum, water-glycol, water-in-oil emulsion, polyol ester, and high-water-base fluids. Phosphate ester fluids require the use of fluorocarbon seals, which are identified in model codes as an "F-" prefix.
8.Check the inlet, outlet and direction of rotation before starting the pump. Turn the shaft of pump evenly and nimbly by hand after fixing the pump. Fill the pump with system fluid through the uppermost port. The housing must be kept full at all times to provide internal lubrication. At initial startup, it may be necessary to bleed air from the pump outlet to permit priming and reduce noise. Bleed by loosening an outlet connection until a solid stream of fluid appears.
9. At startup, If the oil viscosity is higher than the suitable viscosity ,the pressure should be limited to 50% or less of their respective rated values until the system has warmed up.

Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for ExcavatorEaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for ExcavatorEaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator

Detailed Photos


Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for ExcavatorEaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator
Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for ExcavatorEaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator

Company Profile

Eaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for ExcavatorEaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for ExcavatorEaton Vickers V10 V20 Series Single Vane Pumps Hydraulic Oil Pump for Excavator

FAQ

Q: Are you trading company or manufacturer?
A: We are factory with more than 20 years experience.

Q: How long for delivery?
A: Generally it is 15-30days as we are customized service we confirm with customer when place order.

Q: What is the MOQ?
A: It depends on what you are buying. Normally, our minimum order is one 20' full container and LCL container (less than a
container load) can be acceptable.

Q: Can you customize my products?
A: Yes, we can customized products with your design drawings like DWG, DXF, DXW, IGES, STEP, PDF etc.

Q: What is your terms of payment?
A: 30% T/T in advance, balance before shipment, or as per discussion.

Q: What about your quality control?
A: * . Checking the raw material after they reach our factory-----Incoming quality control(IQC)
* . Checking the details before the production line operated
* . Have full inspection and routing inspection during mass production----In-process quality control(IPQC)
* . Checking the goods after they are finished----Final quality control(FQC)
* . Checking the goods after they are finished----Outgoing quality control(QC)
* . 100% inspection and delivery before shipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier